SOLUTION
Browse full water treatment spare parts at Shuitianlan(STL): ultrapure resin series, filtration membrane products, various filter vessels, branded EDI modules, multiple types of UV sterilizers and original imported water pumps for industrial water purification.
ABOUT US
Shuitianlan(STL) is a professional water treatment consumables distributor focusing on membrane, resin, filter, EDI and disinfection products. With stable supply chain and rich project experience, we serve global water engineering companies with cost-effective products & technical support.
Shuitianlan(STL) matches targeted consumable supporting schemes for petrochemical wastewater recycling, food & beverage production pure water, municipal drinking water purification, helping enterprises reduce water treatment operation cost.
Release Shuitianlan(STL)’s latest product supply information, industry policy & technology trends, and sort out common FAQs of membrane, resin, filter operation & maintenance to solve customers’ daily use problems.
Welcome global water treatment engineering merchants, project contractors to contact Shuitianlan(STL) for product quotation, sample application, customized supporting and long-term supply cooperation.
LANMO LM‑EU8040P
Integrated Spiral‑Wound Ultrafiltration Membrane Element for E‑Coat Paint.
Product Description:
Membrane separation layer material: PVDF (Polyvinylidene Fluoride)
Permeate tube: UPVC Seal: EPDM (Ethylene‑Propylene‑Diene Monomer)
Active membrane area: 290 ft² (26.9 m²)
Operating Parameters:
Maximum inlet pressure: 65 psi (4.4 bar)
Recommended inlet pressure: 44‑60 psi (3.0‑4.1 bar)
Recommended outlet pressure: 15‑40 psi (1.0‑2.7 bar)
Maximum operating temperature (@ pH=8): 125 ℉ @56 psi (51.6℃ @3.9 bar)
Allowable pH – Continuous operation: 2.0‑10.0 pH @125 ℉ (51.6℃)
Allowable pH – Short‑term cleaning (30 min): 1.5‑11.5 pH @125 ℉ (51.6℃)
Design Parameters:
Feed flow rate: 65‑80 GPM (246‑303 LPM)
Permeate flow rate: 2.4‑4.6 GPM (9.0‑17.0 LPM)
Important Notes:
The membrane element must be kept wet. When the system is shut‑down, elements shall remain filled with pure water or permeate liquid; otherwise irreversible damage will occur.
No antiscalant of any type shall be applied to the e‑coat ultrafiltration system.
Silicone‑containing substances (water‑proof sprays, lubricants, greases, etc.) and phosphating sludge are prohibited from entering the ultrafiltration system. Their ingress will result in complete and irreversible membrane fouling.
Paint feed entering the ultrafiltration system shall be pre‑filtered by precision filters with 25‑50 μm pore size. Proper filtration effectively reduces the risk of membrane fouling.
Protective measures shall be implemented to avoid back‑pressure or vacuum conditions during system shutdown. Excessive back‑pressure or vacuum will cause membrane delamination.
Avoid “low‑flow” conditions (bypass valve open or circulation pump stopped), which will readily cause paint deposition on membrane surface.
Regular laboratory testing and adjustment of bath‑solution composition parameters. Relatively high additive content, lower pH value and lower conductivity of carry‑over from workpieces into bath can effectively mitigate membrane fouling and extend membrane service life.
Before feeding paint into the ultrafiltration system, ensure full circulation and maturation to achieve homogeneous paint mixing; otherwise unsatisfactory membrane performance will occur.

| Item | Inch (mm) |
|---|---|
| A | 46.1 (1171) |
| B | 42.75 (1086) |
| C | 8.63 (219.2) |
| D | 39.5 (1003) |
To enquire about prices for authentic industrial water treatment consumables such as RO membranes, NF membranes, UF membranes, ion exchange resins and EDI modules, please use the contact details below.