
SOLUTION
Browse full water treatment spare parts at Shuitianlan(STL): ultrapure resin series, filtration membrane products, various filter vessels, branded EDI modules, multiple types of UV sterilizers and original imported water pumps for industrial water purification.
ABOUT US
Shuitianlan(STL) is a professional water treatment consumables distributor focusing on membrane, resin, filter, EDI and disinfection products. With stable supply chain and rich project experience, we serve global water engineering companies with cost-effective products & technical support.
Shuitianlan(STL) matches targeted consumable supporting schemes for petrochemical wastewater recycling, food & beverage production pure water, municipal drinking water purification, helping enterprises reduce water treatment operation cost.
Release Shuitianlan(STL)’s latest product supply information, industry policy & technology trends, and sort out common FAQs of membrane, resin, filter operation & maintenance to solve customers’ daily use problems.
Welcome global water treatment engineering merchants, project contractors to contact Shuitianlan(STL) for product quotation, sample application, customized supporting and long-term supply cooperation.
VONTRON ZERO-FR10 ZERO Liquid Discharge(ZLD)- ZERO series.
Product Presentation:
ZERO-FR10 element is one of the industry’s most advanced fouling resistant element technology special designed for high TDS level 5000-15000 ppm, and high COD wastewater reclaiming in zero liquid discharge process. Base on the new generation of membrane separation layer technology and unique component structure, It is a low pressure drop, long cleaning cycle, high chemical cleaning resistance membrane element product.
Application:
Reuse of High Salt and High COD Wastewater.
Primary Concentration and Reduction Stage of Zero Liquid Discharge Technology
Suitable for TDS 5-15g/L of Feed Water.
Product Performance:

1、Operating pressure 225 psi (1 .55 MPa) 2000 mg/L NaCl solution Temperature at 25℃ pH 7.0 ± 0.5 Recovery rate at 15%.
2、Each membrane element may have ±20% variation of permeate flow.
3、Minimum salt rejection 99.6%.
Operating Conditions & Limits:
Maximum operating pressure psi(MPa) ------- 600(4 .14)
Maximum feedwater temperature ℃ -------45
Maximum inlet flow rate m3/h ------- 17
Maximum concentration of free chlorine mg/L ------ 0.1
Maximum pressure drop per element psi(MPa)------- 15(0.1)
Allowed pH range for feedwater in operation ------- 2-11
Allowed pH range for chemical cleaning -------1-13
Maximum feedwater flow SDI15 ------- 5
Important information:
Before the membrane element leaves the factory, The dry membrane element has no preservation solution, The wet membrane element has 1.0% sodium bisulfite (in winter, add 10% of propylene glycol antifreeze) as the preservation solution for storage treatment and use vacuum packaging.
Dry membrane elements should always be maintained wet after Soaking; when wet membrane elements are not used for a long time, preservation solution is needed to soak the elements.
When the membrane element is used for the first time, it is recommended to flush it first for15-25 minutes at low pressure (not suitable for soaking or soaking overnight), and then flush it for 60-90 minutes at high pressure (the water flow should not be less than 50% of the system design water flow).
The permeate water and concentrated water within the first hour of the initial operation of the membrane element should all be discharged.
The operating limits and operational guidelines given in this technical information are part of the limitations of the three-year warranty on the membrane element.
The addition of any chemicals that may affect the membrane element during storage and operation is prohibited, and Vontron Technology will not be liable for any consequences arising from the use of such chemicals.
Please refer to the Product Manual for details on installation, commissioning, storage, and transportation of membrane elements.
Dimensions and Packaging:

To enquire about prices for authentic industrial water treatment consumables such as RO membranes, NF membranes, UF membranes, ion exchange resins and EDI modules, please use the contact details below